BPYHS - PRIMARY BATTERY,MERCURY BA1083/U

  • MSDS: BPYHS
  • Manufacturer: BATTERY TECHNOLOGY COMPANY
  • Product Name: PRIMARY BATTERY,MERCURY BA1083/U
  • National Stock Number: 6135-00-557-0174
Product Identification

Product ID:PRIMARY BATTERY,MERCURY BA1083/U
MSDS Date:11/29/1984
FSC:6135
NIIN:00-557-0174
MSDS Number: BPYHS

Responsible Party
BATTERY TECHNOLOGY COMPANY
NEW HIGHWAY 64E
LEXINGTON, NC 27292-2037
US

Emergency Phone: 704-249-9101

Info Phone: 704-249-9101

Cage: 06121

Contractor
DURACELL USA (ALIAS BATTERY TECHNOLOGY COMPANY)
LEXINGTON, NC 27292-2037 US

Telephone: 617-449-7600

Cage: 2A917

Ingredients

POTASSIUM HYDROXIDE (SARA III).176 G;BP 2408F;VP 1 MMHG @

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: 11.1%

OSHA PEL 2 MG/M3 CEILING

ACGIH TLV: 2 MG/M3 CEILING

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


MERCURIC OXIDE (SARA III).604 G;SPEC GRAVITY 3.97

CAS: 21908-53-2

RTECS: OW8750000

Fraction By Weight: 38.0%

OSHA PEL 0.1 MG(HG)/M3 SKIN

ACGIH TLV: 0.1 MG(HG)/M3 SKIN


MERCURY (SARA III).2.3 G;BP 674F;VP 1 MMHG @ 186C;SPEC

CAS: 7439-97-6

RTECS: OV4550000

Fraction By Weight: 5.0%

OSHA PEL 0.1 MG(HG)/M3 SKIN

ACGIH TLV: 0.05 MG/M3 SKIN

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB

Hazards

LD50 LC50 Mixture:NOT KNOWN
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ARTICLE. NO HAZARD IS EXPECTED IN
NORMAL SERVICE. SPILLED CONTENTS(POTASSIUM HYDROXIDE) MAY CAUSE
BURNS TO SKIN AND EYES.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES:POTASSIUM HYDROXIDE IS CAUSTIC CAUSING
DAMAGE TO EYE.SKIN:POTASSIUM HYDROXIDE IS CAUSTIC CAUSING DAMAGE TO
SKIN.
Medical Cond Aggravated by Exposure:NOT KNOWN

First Aid

First Aid:EYES:FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES AND SEE PHYSICIAN.SKIN:WASH WITH WATER IMMEDIATELY.

Fire Fighting

Flash Point:NONE
Extinguishing Media:USE MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS (SCBA)
AND FULL TURNOUT GEAR WHEN BATTERIES ARE IN FIRE.
Unusual Fire/Explosion Hazard:CAN EXPLODE WHEN SUBJECTED TO EXCESSIVE
HEAT.

Accidental Release

Spill Release Procedures:PICK UP BATTERIES AND PLACE IN AN APPROPRIATE
CONTAINER FOR DISPOSAL.

Handling

Handling and Storage Precautions:STORE AT ROOM TEMPERATURE.
Other Precautions:DO NOT BURN,CAN EXPLODE WHEN SUBJECTED TO EXCESSIVE
HEAT.

Exposure Controls

Respiratory Protection:CONTACT LOCAL SAFETY/INDUSTRIAL HYGIENE OFFICE
TO DETERMINE IF RESPIRATORY PROTECTION IS REQUIRED .
Ventilation:CONTACT LOCAL SAFETY/INDUSTRIAL HYGIENE OFFICE TO DETERMINE
IF LOCAL EXHAUST VENTILATION IS NEEDED .
Protective Gloves:NEOPRENE,RUBBER,LATEX-NITRILE GLOVES.
Eye Protection:CHEMICAL SAFETY GOGGLES .
Other Protective Equipment:NOT KNOWN
Work Hygienic Practices:AVOID SKIN AND EYE CONTACT.
Supplemental Safety and Health
DIMENSIONS OF BATTERIES:GROSS WEIGHT (LB): 3.5;OUTSIDE PACKAGE
DIMENSIONS (INCHES):2 21/32(L) X 2 21/32(W) X 5 1/4(H). RECORD WAS
EDITED BY FP-D ON 96312.

Chemical Properties

HCC:N1
Solubility in Water:INSOLUBLE
Appearance and Odor:POTASSIUM HYDROXIDE:CLEAR LIQUID.MERCURY:SILVER.
MERCURY OXIDE:ORANGE-RED POWDE

Stability

Stability Indicator/Materials to Avoid:YES
NOT KNOWN
Stability Condition to Avoid:TEMPERATURES ABOVE 500F.
Hazardous Decomposition Products:MERCURIC OXIDE(DECOMPOSES TO OXYGEN
AND MERCURY).
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE, AND LOCAL REGULATIONS.COORDINATE WITH SUPPORTING
INSTALLATION AND/OR MACOM ENVIRONMENTAL OFFICE PRIOR TO DISPOSAL
.MAY BE RETURNED FOR RECLAMAT ION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.